New research reveals key pH levels for efficient power plant desulfurization.
The researchers studied how to operate a 200 MW desulfurization plant efficiently by adjusting the pH of the slurry. They found that changing the pH of the slurry in the absorption tower can affect the desulfurization efficiency, based on the concentration of SO2 in the combustion gas. This information is crucial for ensuring the proper functioning of the desulfurization plant at the Seocheon thermal power plant.